Skip to content
LightCurve
WebsiteApp

Analyse

Period search

Lomb–Scargle periodogram and folded light curve of the measured magnitudes.

In the Measurement tab of the curves, the Periodogram view computes a generalised Lomb–Scargle periodogram (floating mean, Zechmeister & Kürster 2009) of the measured magnitudes. It handles irregular sampling.

Setting Value
Shortest period 2 × the typical spacing of the measurements
Longest period Half the duration of the series
Peaks proposed The 5 strongest local maxima
  • ×2: a light curve with two maxima per turn (frequent for elongated bodies) gives a peak at half the true period. The button doubles the period.
  • Use sets the rotation period of the model.
  • The Folded view plots the measurements against the rotation phase for the chosen period.